We use cookies to enable all functionalities for best performance during your visit and to improve our services by giving us some insight into how the website is being used. Continued use of our website without having changed your browser settings confirms your acceptance of these cookies. For details please see our privacy policy.
×

piezoelectric accelerometer

These articles are all highly relevant piezoelectric accelerometer. I believe this information can help you understand piezoelectric accelerometer's professional information. If you want to know more, you can contact us at any time, we can provide you with more professional guidance.
  • 2026-11-12

    Advantages and Disadvantages of Wired Piezoelectric Vibration‑Monitoring Solution
    This document illustrates the merits of wired IEPE piezoelectric vibration monitoring. Compared with wireless LoRa MEMS monitoring, the wired solution realizes real‑time collection of complete raw vibration waveforms with high sampling rates. It delivers reliable communication free of wireless interference and requires no battery maintenance. Capable of transient shock capture and advanced spectrum analysis, it is particularly fit for early‑fault diagnosis and long‑term continuous online monitoring of pumps, motors and bearing‑equipped rotating machinery.
  • 2026-11-12

    Optimization Solution for Comprehensive Online Condition‑Monitoring System of Water Pump Units
    This solution introduces an edge‑cloud collaborative online condition‑monitoring system for water pump units. Using IEPE accelerometers and Pt100 temperature sensors, it collects vibration velocity and temperature data to detect typical faults such as bearing wear, rotor unbalance and cavitation. Supporting local graded alarms and multi‑protocol upload to private cloud platforms, it enables predictive maintenance, reduces unplanned shutdown risks and improves pump‑unit O&M efficiency.
  • 2026-11-12

    Technical Solution for The Vibration Monitoring System of Key Pumps And Fans
    Rotating machinery such as key pumps and fans operate in continuous running conditions for long‑term service. Issues including unbalance, misalignment, mechanical looseness, bearing faults, gear failures and other defects may occur in components such as bearings, rotors, couplings, gears and foundations during operation. Conventional manual inspection is subject to long monitoring cycles, insufficient data continuity and delayed detection of anomalies. Therefore, this solution adopts the technical architecture consisting of vibration sensors, edge‑computing acquisition units and data analysis platforms to implement continuous condition‑based vibration monitoring for critical pumps, fans and other equipment. The system acquires operating‑condition signals of equipment via vibration, displacement and temperature sensors installed at key measuring points of equipment. Signals are wired to edge‑computing acquisition units, which complete data acquisition, signal processing, feature‑value
  • 2026-10-22

    Principles of IEPE Accelerometers & On-Site Application Troubleshooting Guide
    This paper introduces IEPE accelerometers (ICP piezoelectric sensors), widely adopted for vibration measurement in equipment fault diagnosis and structural tests. Integrated with impedance conversion circuits, they dispense with external charge amplifiers, yet suffer from typical signal faults in field use. This vibration classroom systematically addresses their principles, specifications, installation and troubleshooting to help engineers avoid common testing mistakes.
  • 2026-10-09

    Miniature Three-Axis Impact Accelerometer
    Miniature Three-Axis Impact AccelerometerProduct OverviewIn dynamic testing of micro-components and high-g impact test scenarios, conventional sensors are often constrained by limited installation space, and their own weight interferes with the structure under test, making it difficult to achieve hi
  • 2026-09-17

    Micro Three-Axis Impact Accelerometer
    Micro Three-Axis Impact AccelerometerDynamic CharacteristicsSensitivity: 0.25 mV/g (±10%)Measurement Range: ±20,000 g pkFrequency Range: 2 to 10 kHz (±5%)1 to 15 kHz (±10%)Mounting Resonance Frequency: ≥100 kHzWideband Resolution: 0.1 g rmsAmplitude Linearity: ≤5%Transverse Sensitivity: <5%Electrica
  • 2026-08-27

    100 mV/g Uniaxial Accelerometer, IEPE Type
    100 mV/g Uniaxial Accelerometer, IEPE TypeSensor Features:• Lightweight and compact• Wide frequency response and high resolution• Built-in circuitry and low-impedance output Sensor Applications:• Modal testing of microstructures Dynamic CharacteristicsSensitivity: 100 mV/gMeasurement Range: ±50 gFre
  • 2026-08-12

    Accelerometer-Temperature Composite Sensor
    Accelerometer-Temperature Composite Sensor (Temperature: Analog Chip)This series of accelerometers are dual-output composite sensors that measure both vibration and temperature. Featuring a stainless steel housing and laser-welded seals, they offer high reliability. With dual-layer shielding that pr
  • 2026-07-08

    Comparative Evaluation of 500 mV/g Accelerometers
    Comparative Evaluation of 500 mV/g Accelerometers: Experimental Measurements of Frequency Response and Immunity to InterferenceForewordWhether it is online monitoring of industrial equipment or modal mechanical testing in a laboratory, the frequency response stability and electromagnetic interferenc
  • 2026-06-06

    Explosion-Proof Accelerometer
    Explosion-proof Accelerometers: Ensuring Safety in the Petrochemical IndustryIn flammable and explosive industries such as petroleum, pipelines, and chemicals—where compressors serve as core production equipment—abnormal equipment vibrations often signal impending failures. If ignored, these issues
  • Total 2 pages  Go to Page